<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-01 18-46-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 57 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 66 kHz 14455 9,9689
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,7 dBr 5,11 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 66 kHz MIN: 10 kHz % above 76 kHz: 9,9689 Acquired: 2025/05/01 18.45.22 Total samples: 14455 Equivalent time: 0:12:02 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,2 dBr MIN: 3,7 dBr AVE: 5,11 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2025/05/01 18.45.21) 18.32 18.34 18.36 18.38 18.40 18.42 18.44 0 2 4 6 Pm [dBr]